Radon Mitigation Systems in Kenwood
Active sub-slab depressurization (ASD) systems, designed and installed custom to your foundation type: slab, basement, or crawl space. Radon abatement and radon mitigation describe the same work, reducing indoor radon to the ANSI/AARST SGM-SF-2023 standard. Every install is verified post-completion with a 48-hour follow-up test. Workmanship warranty terms confirmed in writing before work begins. Kenwood sits within our service area for Greater Cincinnati and Northern Kentucky, with same-week scheduling typical for routine jobs.
Typical pricing in Kenwood
$1,200-$2,400
Pricing varies by job specifics. Free phone or on-site quotes; fixed pricing once the technician has assessed the job.
Radon Mitigation Systems in Kenwood: established mid-century single-family foundations and Cincinnati Arch geology
Kenwood's 1950s-1970s housing sits on full basements, many now finished as family rooms and bedrooms, which places occupied space directly on the slab. Post-and-beam basement layouts in this stock usually allow a single central suction point. Kenwood sits on the Cincinnati Arch geology (fractured Ordovician limestone and shale) that drives elevated regional radon exposure across the entire Greater Cincinnati metro, including Hamilton County.
In ZIP 45236 (Kenwood), 17% of the 1,783 tests reported to the Ohio Department of Health since 2010 came back above 4.0 pCi/L, the level at which EPA recommends fixing the home. A Kenwood house above that line is routine work for a sub-slab system, not an edge case.
In Hamilton County, sub-slab depressurization has to account for both ends of the housing stock: a single cored suction point on Cincinnati's 1920s-1960s block basements, and, on the pre-Civil-War stone rubble stock in Over-the-Rhine and the West End, sealing at the wall itself in addition to the slab, because soil gas enters through the fractured Ordovician limestone-and-shale wall as much as through any single crack.
In Ohio, radon mitigation is licensed work under ORC Chapter 3723 (Ohio Department of Health Radon Licensing Program), done to the state rules in OAC 3701-69; the consensus standard for existing homes is ANSI/AARST SGM-SF-2023. The Ohio Department of Health Radon Licensing Program oversees radon program compliance for Kenwood, and Ohio licensure under ORC 3723.02 applies to any contractor performing mitigation work in the state.
- County
- Hamilton, OH
- Geology
- Cincinnati Arch (Ordovician limestone and shale)
- Tests in ZIP 45236
- median 1.9 pCi/L, 17% above 4.0 (1,783 since 2010, ODH)
- EPA action level
- 4.0 pCi/L on long-term average
- Service category
- Mitigation